• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Peer Review Process
  • Guide for Authors
  • Submit Manuscript
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
Journal of Fundamental and Clinical Research
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 5 (2025)
Volume Volume 4 (2024)
Volume Volume 3 (2023)
Issue Issue 2
Issue Issue 1
Volume Volume 2 (2022)
Volume Volume 1 (2021)
Kheir, M., Younis, J., Mokhtar, A. (2023). Effect of Fabrication Technique and Margin Design on the Marginal Fit of Interim Fixed Dental Prosthesis (An In-Vitro Study). Journal of Fundamental and Clinical Research, 3(2), 190-206. doi: 10.21608/jfcr.2023.226432.1052
Mohamad Kheir Jihad Kheir; Jihan Farouk Younis; Ashraf Mokhtar. "Effect of Fabrication Technique and Margin Design on the Marginal Fit of Interim Fixed Dental Prosthesis (An In-Vitro Study)". Journal of Fundamental and Clinical Research, 3, 2, 2023, 190-206. doi: 10.21608/jfcr.2023.226432.1052
Kheir, M., Younis, J., Mokhtar, A. (2023). 'Effect of Fabrication Technique and Margin Design on the Marginal Fit of Interim Fixed Dental Prosthesis (An In-Vitro Study)', Journal of Fundamental and Clinical Research, 3(2), pp. 190-206. doi: 10.21608/jfcr.2023.226432.1052
Kheir, M., Younis, J., Mokhtar, A. Effect of Fabrication Technique and Margin Design on the Marginal Fit of Interim Fixed Dental Prosthesis (An In-Vitro Study). Journal of Fundamental and Clinical Research, 2023; 3(2): 190-206. doi: 10.21608/jfcr.2023.226432.1052

Effect of Fabrication Technique and Margin Design on the Marginal Fit of Interim Fixed Dental Prosthesis (An In-Vitro Study)

Article 8, Volume 3, Issue 2, December 2023, Page 190-206  XML PDF (611.85 K)
Document Type: Original research articles
DOI: 10.21608/jfcr.2023.226432.1052
View on SCiNiTO View on SCiNiTO
Authors
Mohamad Kheir Jihad Kheir email orcid 1; Jihan Farouk Younisorcid 2; Ashraf Mokhtarorcid 3
1Department fixed prosthodontics, Misr International University
2Professor of Fixed Prosthodontics, Fixed Prosthodontics Department, Faculty of Dentistry, Cairo University, Cairo, Egypt.
3Fixed prosthodontics department, Dentistry, Cairo University, Cairo, Egypt.
Abstract
Background: There is limited evidence available regarding the effectiveness of various digital manufacturing techniques for producing interim prosthesis with different finish line designs. Aim: The objective was to evaluate the influence of CAM techniques, 3D printed and milled on the vertical margin gap of interim fixed dental prosthesis using two finish line designs. Materials and Methods: Two prepared abutment teeth were designed with finish line designs (shoulder and knife-edge) to receive a 3-unit interim prosthesis (polymethyl methacrylate and microfilled hybrid resin). The reference models were 3D printed (n=28), and an optical impression was performed to design FDPs on CAD software. Group A milled with shoulder finish line. Group B milled with knife-edge finish line. Group C 3D-printed with shoulder finish line. Group D 3D-printed with knife-edge finish line. Samples were cemented with long-term temporary cement. Vertical marginal fit was assessed using stereo-optical microscope before and after thermocycling Results: Marginal gaps in both techniques were influenced by thermocycling. The knife-edge finish line showed a higher gap when milled. Overall gap distance for 3D-printed knife-edge and shoulder finish line before (20-74.8 µm, 17.8-91µm) and after thermocycling (34-103µm, 33-112µm). Overall gap distance for milled knife-edge and milled finish lines before (43-111.8 µm, 17.2-93µm) and after thermocycling (62-141 µm, 27-103µm). Conclusion: Thermocycling showed a negative effect on vertical marginal adaptation in both techniques. Vertical marginal gap of the interim restorations fabricated by the two techniques was within the acceptable clinical range of ≤120μm.
Keywords
finish line designs; marginal fit; milling method; three-dimensional printing method; tooth-supported FDPs
Main Subjects
Pharmaceutical, Dental, and medical disciplines whether they are descriptive, analytical, experimental, or basic studies